S80 T6 Executive L6-2.8L Turbo VIN 90 B6284T (2001)
Install the drainage section using silicon.
Caution! Clean carefully before installing! Ensure that the surfaces are clean and free of adhesive /silicone residue and other dirt.
To synchronize the slides: Press/Move the slides forward as far as they will go on both sides before connecting the motor and control module.
Check for leakage. See Sun roof, leak test See: Testing and Inspection/Component Tests and General Diagnostics.
Calibrate the control module. See Sun roof module (SRM), calibrating See: Sunroof / Moonroof Module/Service and Repair/Procedures.