Blower Motor: Procedures

Removing the Fan (Fan Housing Removed)

Removing The Fan (Fan Housing Removed) 

-

Remove the soundproofing panel on the passenger side.

-

If the car is equipped with an alarm, remove the screw and slide the "Ultrasonic and glass breakage control modules" to one side.

-

Disconnect the connector from the blower fan motor.

-

Cut 10 x 7 cm in the insulation panel and bend the panel.

-

Remove three screws.

-

Pull the motor down and pull it out (turn the motor 90 degrees).

Installation 

-

Check the seals.

-

Install the motor using a twisting movement.

-

Install three screws.

-

Connect the connector for the blower fan motor.

-

If the car is equipped with an alarm, install "the ultrasonic and glass breakage control modules" and the screw.

-

Install the insulation panel and secure it with tape.

-

Check the function.

-

Install the soundproofing panel on the passenger side.

Blower Fan Housing

Removing The Blower Fan Housing 

Procedures|Page 9113 > < A/C - Unpleasant Odors From Vents|Page 9110