Route the return hose forward to the fluid reservoir. Ensure that the hose is not subjected to tension loading and does not rub. Secure a new hose clamp
on the hose.
Connect the return line to the fluid reservoir and move the new hose clamp into position and secure it.
Position the fluid reservoir. Tighten to 10 Nm.
Position the hoses in their respective hose mountings.

Reinstalling the air intake hose, air cleaner (ACL) housing and fusebox (turbocharged gasoline engines)