V70R L5-2.5L Turbo VIN 52 B5254T4 (2007)
Ground connection for cable under member
-
Drill a 4 mm (5/32") hole
-
Apply rust protection and connect the ground cable using the 4.8 mm (3/16") flanged screw and serrated washer supplied.
Note! Connect the ground cable to the side member, not to the subframe.
-
Tie up excess cable using new tie clips.
Fig. A
-
Clean the heater location to ensure the best possible transfer of heat to the cylinder block. Also clean the internal thread
-
Slide the heat shield over the heater cable
-
Take the sealing sleeve and heater cable from the kit. Connect the cable to the heater and fit the sleeve over the joint in the cable
-
Mount the heater on the cylinder block as illustrated
-
Fit the spacer (1) (t = 10 mm / 25/64") between the clamp (2) and bracket (3) on the cylinder block
-
Fit the outer spacer (4) (t = 32 mm / 1 1/4") to the outer side of the clamp (2)
-
Tighten the heater in position using the screw supplied. Torque to 16 Nm (12 lbf.ft.).
Fig. B