Compressor Clutch: Adjustments

TTTO27 Checking clearance

-

Check clearance between coupling plate and pulley using a feeler gauge:
-

clearance should be between 0.3 and 0.5 mm (0.012 in and 0.020 in).

-

0.3 mm (0.012 in) clearance all the way round

-

0.6 mm (0.024 in) should not go in anywhere

-

If clearance is not within the stated values; Replace shims. The following dimensions are available:
-

0.2 mm (0.008 in)

-

0.3 mm (0.012 in)

-

1.0 mm (0.039 in)