Install sensor 9512986 on the wastegate shaft.
Position the sensor so that the pin is about 2-5 mm from max pushed in position.
Ensure that the sensor is positioned to allow free movement with at least 15 mm in the direction of the wastegate shaft

Use pressure gauge ,, and pressure regulator

Install the following items:

-

951 2985 Measuring tools See: Tools and Equipment/951 2985 Measuring Tools 

-

951 2986 Measurement sensor  See: Tools and Equipment/951 2986 Measurement Sensor 

-

951 2775 Cylinder leak tester See: Tools and Equipment/951 2775 Cylinder Leak Tester 