volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Thermostatic Expansion Valve to Connector Block Line|Page 2703 > < Thermostatic Expansion Valve to Connector Block Line
Page 2
background image

1. Remove the connector.
2. Torque: M6, 10 Nm

Installation

Change and lubricate the O-rings with compressor oil.

To install, reverse the removal procedure.

Vacuum-pump the AC-system.  Refer to: Vacuum pumping See: Heating and Air Conditioning/Service and Repair/Vacuum Pumping 

Fill the air conditioning system with refrigerant.  Refer to: Refrigerant, filling See: Heating and Air Conditioning/Service and Repair/Refrigerant, Filling 

Leak-trace the air conditioning system.  Refer to: Leak detection, tracer agent See: Heating and Air Conditioning/Testing and Inspection/Component
Tests and General Diagnostics/Leak Detection, Tracer Agent 
Or: Refer to: Leak tracing, electronic leak tracer See: Heating and Air Conditioning/Testing and Inspection/Component Tests and General
Diagnostics/Leak Tracing, Electronic Leak Tracer 

Carry out a performance test on the climate control system.  Refer to: Climate control system, check See: Heating and Air Conditioning/Testing and
Inspection/Component Tests and General Diagnostics/Climate Control System, Check 

Thermostatic Expansion Valve to Connector Block Line|Page 2703 > < Thermostatic Expansion Valve to Connector Block Line