Route the cable harness from the tow bar connector through the hole in the floor.

-

Adjust the position of the rubber seal (1) so that there is not excessive cable slack under the car.

-

Install the rubber seal in the hole.

-

Route the cable harness as shown in the illustration over the rear edge of the left-hand side member to the fuse holder.

Illustration B

-

Secure the cable harness to the cable harness behind the battery with tie straps (2) from the kit.

-

Connect the routed ground cable to the grounding point (3) behind the battery and tighten the grounding screw securely.

-

Detach the trailer module (TRM) from the Velcro fastener on the back side of the plate in front of the fuse holder.

-

Plug in the tow bar wiring connectors:
-

green (GN) and grey (GR) connectors to the control module.

-

black (SB) connector to the fuse holder.

-

Reinstall the control module.

-

Secure the excess cable with a tie strap from the kit.