volvo Workshop Repair Guides

Volvo Workshop Service and Repair Manuals

Ambient Temperature Sensor / Switch HVAC > < A/C - Excessive Floor Vent Airflow|Page 11355
Page 2
background image

Position a weatherstrip tool on the short side of the vent.
Release the catches closest to the weatherstrip tool using a small screwdriver. At the same time pry out the vent.

Note! Do not break off the small catches.

Disconnect the connector for the switch for the hazard warning signal flasher.

Installing the center vent and valve housing in the dashboard

Connect the connector to the switch for the hazard warning flashers.
Press the vent and valve housing into place.

Note! Ensure that the vent is correctly connected to the air duct and all the catches have engaged.

Check the function.

Vents B and C-post, replacing

Remove and install the vents. See Panel B-post, replacing See: Body and Frame/Interior Moulding / Trim/Trim Panel/Service and Repair/Panel B-Post,
Replacing and Panel C-post, replacing See: Body and Frame/Interior Moulding / Trim/Trim Panel/Service and Repair/Panel C-Post, Replacing.

Ambient Temperature Sensor / Switch HVAC > < A/C - Excessive Floor Vent Airflow|Page 11355