Connect:

-

manometer 999 5646 Pressure gauge See: Tools and Equipment/999 5646 Pressure Gauge to the pressure regulator hose

-

pressure regulator 999 5544 Regulator See: Tools and Equipment/999 5544 Regulator to the manometer.

Note! When taking readings the manometer must always hang vertically from its hook. This is to ensure that the correct values are obtained.
Set the 3-way junction connector handle in its middle position.

Screw out the adjustment screw for the pressure regulator completely.
Connect compressed air to the pressure regulator.
Screw in the adjustment screw for the pressure regulator so that the manometer displays the value applicable to the relevant engine. See the table.
3-way junction connector has a vent (drilled hole) where it connects to the pressure regulator. This is to facilitate setting the correct pressure.

Checking and adjusting

Wastegate Actuator|Adjustments|Page 5802 > < Wastegate Actuator|Adjustments|Page 5800