Do Not Sell My Personal Information
volvo Workshop Repair Guides

Volvo Workshop Manuals

< PREV PAGE NEXT PAGE >
Page 33
background image

-

If a control module is "disruptive", the voltage is usually above 0.7 V

-

If this is the case, cut the power to the control modules in accordance with the method described about to find the fault cause

-

Verify that the correct control module was faulty by repeating the fault, with and without the faulty control module connected in the CAN network.

Note! Following faults with "babbling" or "disruptive" control modules, some control modules may remain in "Limp-home mode" even after
the ignition key has been removed and inserted in the ignition switch again. To remedy this, disconnect and reconnect the battery negative
terminal to restore the control modules to normal function.

Powertrain Management > Computers and Control Systems > Information Bus > Component Information > Description and Operation > The Controller Area Network (CAN) > Page 4874