RL V6-3.7L (2009)
55. Disconnect the fuel pump control module 10P connector. See: Fuel Delivery and Air Induction/Fuel Pump/Fuel Pump Control Unit/Service and
Repair
56. Check for continuity between the fuel pump control module 10P connector terminal No. 3 and body ground.
Is there continuity?
YES - Repair short in the wire between the fuel pump control module and PGM-FI main relay 2 (FUEL PUMP). Also replace the No. 19
FUEL PUMP (20 A) fuse.
NO - Check the fuel pump control module, and replace it if necessary. See: Fuel Delivery and Air Induction/Fuel Pump/Fuel Pump Control
Unit/Service and Repair Also replace the No. 19 FUEL PUMP (20 A) fuse.
57. Jump the SCS line with the HDS.
58. Disconnect PCM connectors D (17P) and E (31P).
59. Turn the ignition switch to ON (II).
60. Measure the voltage between PCM connector terminal D6 and body ground.
Is there battery voltage?
YES - Go to step 61.
NO - Repair open in the wire between the No. 19 FUEL PUMP (20 A) fuse and the PCM (D6).
61. Measure the voltage between PCM connector terminal E5 and body ground.