WARNING
|
Note
The maximum specification for pressure in the accumulator, which is controlled by software and adjusted via the pump, is 60 bar. The pump is switched off if the pressure exceeds this value. When the pressure drops to 42 bar due to gearshifts, the pump is switched on again. In the event of a software fault, it is possible for the pressure to reach approx. 75 bar. The pressure relief valve then opens automatically. |