‒ → Connect hand-held multimeter V.A.G 1526 (resistance test range) to contacts 2 and 3 on connector for engine speed sender using test lead from V.A.G 1594.
Specified value: 730...1000 ω.
Note:
The resistance figure for the engine speed sender is associated with a temperature of 20 oC.
The resistance increases with increasing temperature.
-
‒ If the value does not match specified value, fit a new engine speed sender.
-
‒ If specified value is attained, connect hand-held multimeter (resistance range) to contacts 2 and 1 (earth) and to contacts 3 and 1 (earth).
Specified value: infinite resistance (open circuit) in each test.
-
‒ If specified value is not attained, renew engine speed sender.
-
‒ If the value does match specified value, test the wiring between the sender connector and the engine control unit as follows:
|