ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Right Side|Page 2171 > < Right Side|Page 2169
Page 2
background image

6. CAUTION:  Do not use metal scrapers, wire brushes, power abrasive discs or other abrasive means to clean the sealing surfaces. These

tools cause scratches and gouges which make leak paths. Use a plastic scraping tool to remove all traces of old sealant. 

NOTE:  The intake manifold is removed for clarity.

NOTE:  The bolts are part of the valve cover and should not be removed.

Remove the LH valve cover.
^

Fully loosen the bolts and remove the valve cover.

^

Inspect the valve cover gasket and clean the mating surface of the cylinder head.

Installation 

1. NOTE:  If not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with Metal Surface Cleaner F4AZ-19A536-A

or equivalent meeting Ford specification WSE-M5B392-RA. Allow to dry until there is no sign of wetness, or 4 minutes, whichever is longer.
Failure to follow this procedure can cause future oil leakage.

Apply a bead of silicone in two places where the engine front cover meets the cylinder head.
Use Silicone Gasket and Sealer F6AZ-19562-AA or equivalent meeting Ford specification WSE-M4G323-A6.

2. Position the (A) valve cover and the valve cover gasket on the (B) cylinder head and loosely install the bolts.

Right Side|Page 2171 > < Right Side|Page 2169