ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Refrigeration Control Module > < Refrigeration Bypass Control Pressure Switch
Refrigeration - Stationary Refrigeration Pressure Regulator Transit 2000.5 (01/2000-05/2006)
Removal and Installation

Removal

WARNING:
WARNING:The stationary refrigeration system must not be connected to the 230-volt circuit during repair work. Failure to observe this instruction can lead to injury.
  1. Evacuate the refrigeration system. For additional information, refer to Section  412-00 Climate Control System - General Information.
  1. Push the driver's seat forwards as far as possible.

  1. Unscrew the band clamp bolts for the stationary refrigeration pressure regulator.
    • Cut the cable ties.

  1. CAUTION:
    CAUTION:Seal off the refrigerant lines and the stationary refrigeration pressure regulator to prevent dirt ingress.
    Remove the stationary refrigeration pressure regulator.
    • Discard the O-rings.

Installation

WARNING:
WARNING:The stationary refrigeration system must not be connected to the 230-volt circuit during repair work. Failure to observe this instruction can lead to injury.
  1. NOTE:
    NOTE:Install new refrigerant line O-rings.
    NOTE:
    NOTE:Coat the O-rings for the refrigerant lines with clean refrigerant oil prior to installation.
    Install the components in the reverse order.
  1. Adjust the stationary refrigeration pressure regulator.
    For additional information, refer to Stationary refrigeration pressure regulator adjustment in this section.

Refrigeration Control Module > < Refrigeration Bypass Control Pressure Switch