RX 400h AWD V6-3.3L (3MZ-FE) Hybrid (2007)
a. Remove the bolt and interlock bracket.
b. Insulate the removed terminal with insulating tape.
NOTE: Make sure that the terminal does not stick out from the insulating tape.
c. Remove the 12 bolts and inverter cover.
23. VERIFY THAT VOLTAGE OF W/CONVERTER INVERTER ASSEMBLY IS 0 V
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Do not allow any foreign objects or water drops to enter the w/ converter inverter assembly.