RX 400h AWD V6-3.3L (3MZ-FE) Hybrid (2007)
a. Using the voltmeter, measure the voltage between the terminals of the 2 phase connectors (N-P).
Standard voltage: 0 V
HINT: Use measuring range of DC 750 V or more on the voltmeter.
24. SEPARATE ENGINE WIRE NO.4
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Do not allow any foreign objects or water drops to enter the w/ converter inverter assembly.
a. Remove the bolt, and disconnect the engine wire No.4 from the w/ converter inverter assembly.
b. Disconnect the connector, clamps and grommet, and separate the engine wire No.4 from the w/ converter inverter assembly.
25. DISCONNECT HIGH VOLTAGE CABLE OF FRONT MOTOR
CAUTION: Wear insulating gloves.
NOTE:
-
Make sure that the inverter converter is temporarily installed before working on the converter inverter assembly.
-
Insulate the removed terminals with insulating tape.
-
Do not allow any foreign objects or water drops to enter the w/ converter inverter assembly.