Q: Does the scan tool MB991958 display "PASSING SW" as normal condition?

YES : Replace the front-ECU. When the passing switch is turned "ON", the headlights (low-beam and high-beam) should illuminate normally.

NO : Refer to INSPECTION PROCEDURE M-6 "ETACS-ECU does not receive any signal from the passing switch."  See: Symptom Diagnostic
Procedures/Inspection Procedure M-6

Inspection Procedure I-5

INSPECTION PROCEDURE I-5: Headlight and Taillight: Headlights do not illuminate when the lighting switch is at "TAIL," and
"PASSING" position, but illuminate at low-beam when the switch is at "HEAD" position. At this position, the headlights cannot be changed to
high beam by operating the dimmer switch.

NOTE:  This troubleshooting procedure requires the use of scan tool MB991958 and SWS monitor kit MB991813. For details on how to use the SWS
monitor, refer to "How to use SWS monitor."  See: Scan Tool Testing and Procedures/How to Use SWS Monitor

TECHNICAL DESCRIPTION (COMMENT)

If the headlights illuminate at low-beam regardless of the lighting switch positions, the headlight operation is in fail-safe mode.

TROUBLESHOOTING HINTS

-

The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector

-

The front-ECU may be defective

DIAGNOSIS

Required Special Tools:

-

MB991223: Harness Set

-

MB992006: Extra Fine Probe

-

MB991958: Scan Tool (M.U.T.-III Sub Assembly)
-

MB991824: V.C.I.

-

MB991827: M.U.T.-III USB Cable

-

MB991910: M.U.T.-III Main Harness A

-

MB991813: SWS Monitor Kit
-

MB991806: SWS Monitor Cartridge

-

MB991812: SWS Monitor Harness (For Column-ECU)

-

MB991822: Probe Harness

Use scan tool MB991958 to select "ECU COMM Check" on the SWS monitor display.

Check the following ECUs:

-

ETACS-ECU

-

Column-ECU

-

Front-ECU

CAUTION:  To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958. Connect special tool MB991910 before connecting special tool MB991812. Be sure to connect special tool
MB991806 after turning on special tool MB991824.

Initial Inspection and Diagnostic Overview|Page 4852 > < Initial Inspection and Diagnostic Overview|Page 4850