mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4851 > < Initial Inspection and Diagnostic Overview|Page 4849
Page 212
background image

Headlights (low-beam) do not illuminate normally : Refer to INSPECTION PROCEDURE I-2 "The headlights (low-beam) do not illuminate
normally.  See: Symptom Diagnostic Procedures/Inspection Procedure I-2

Headlights (high-beam) do not illuminate normally : Refer to INSPECTION PROCEDURE I-3 "The headlights (high-beam) do not illuminate
normally.  See: Symptom Diagnostic Procedures/Inspection Procedure I-3

STEP 2. Check the input signal by using "DATA LIST" menu of the SWS monitor.

Turn the passing switch to the "ON" position before checking input signals from the passing switch.

CAUTION:  To prevent damage to scan tool MB991958, always turn the ignition switch to the "LOCK" (OFF) position before connecting or
disconnecting scan tool MB991958. Connect special tool MB991910 before connecting special tool MB991812. Be sure to connect special tool
MB991806 after turning on special tool MB991824.

1. Connect the special tool. Refer to "How to connect SWS monitor."  See: Scan Tool Testing and Procedures/How to Connect SWS Monitor
2. Operate scan tool MB991958 according to the procedure below to display "COLUMN ECU."

a. Select "Interactive Diagnosis."
b. Select "System select."
c. Select "SWS."
d. Select "SWS MONITOR."
e. Select "Data List."
f.

Select "COLUMN ECU."

3. Check that normal conditions are displayed for the items described in the table below.

Initial Inspection and Diagnostic Overview|Page 4851 > < Initial Inspection and Diagnostic Overview|Page 4849