| Disconnect electrical connection -6- from the intake manifold flap motor -V157-. |
–
| Disconnect the coolant hose -3- from the mechanical exhaust gas recirculation valve. |
–
| Release the air hose from the intake connection pipes, lifting the retention clip to do so -1-. |
–
| Unscrew the bolts -2- and -4- and remove the connection tubing from the intake manifold along with the exhaust gas recirculation valve. |
Installation is carried out in the reverse sequence; note the following: |
Note t
| Renew gaskets and seals. |
–
| Fit the charge air system lines, follow the instructions during this → Chapter. |
|
|
|