| Insert the seals -A- a little way into the valve stems. |
–
| Place the control unit in the hydraulic unit taking care not to tilt it. |
This pushes the seals into their final position. |
–
| Using the Torx screws provided, tighten the hydraulic unit and the control unit diagonally to the respective tightening torque in stages. |
Note t
| The same hydraulic unit should not be fitted with a new control unit more than twice, otherwise the elastic seal will not provide a suitable seal. |
t
| A control unit which has been fitted previously should not be fitted again. |
|
|
|