| Tightening torque of screws -7-: 1 Nm |
| The trim panel -6- is clipped to the control -5- (press off carefully). |
–
| Disconnect plug connection -3-. |
–
| Detach flex shaft -4- for positioning unit for air distribution flaps and flex shaft -2- for positioning unit of temperature flap → Chapter. |
Installation is carried out in the reverse order. |
|
|
|