skoda Workshop Repair Guides

Skoda Workshop Service and Repair Manuals

Testing secondary air injection valve N112 > < Testing combination valve
Test secondary air pump
Test secondary air pump
Special tools and workshop equipment required
t  Vehicle system tester -V.A.G 1552 - with cable -V.A.G 1551/3A, 3B oder 3C-
t  Multimeter, e.g. -V.A.G 1526 A -
Test conditions
   
l  Fuse for secondary air pump relay - J299--arrow- in main fuse box on battery o.k.
l  Secondary air pump relay -J299- is o.k.
l  Intake hose for secondary air pump is not blocked or kinked.
Test sequence
–  Remove engine cover → Chapter.
–  Remove pressure hose guided from the secondary air pump to the combination valve.
–  Actuate the secondary air pump relay by means of the final control diagnosis → 2.0 ltr./85 kW Engine, Fuel Injection and Ignition System → Rep. Gr.01.
The secondary air pump must start at intervals and air must flow out at the outlet connection.
–  If the pump does not start, check the voltage supply of the pump.
–  Disconnect the 2-pin plug at the secondary air pump and connect the multimeter for measuring the voltages.
–  Actuate the secondary air pump relay via the final control diagnosis.
–  Specified value: alternately 0...12V in switching rhythm of the pump relay.
–  If the specified value is not reached, check wiring according to the current flow diagram.
–  If the nominal value is reached, replace the secondary air pump.
  N24-0776

Testing secondary air injection valve N112 > < Testing combination valve