1. Measure the present alignment.

Camber: -0°15' (-0.25°) 
Caster: 2°40' (2.67°) 

2. Mark the difference between the standard value (A) and the measured value (B) on the adjustment chart.

Standard value:

Camber: 0°05'(0.08°) 
Caster: 2°30' (2.5°) 
Formula: A - B = C 
Camber: 0°05'- (-0°15') = 0°20' 
Caster: 2°30'- 2°40' = -0°10' 