Guide – Water Gutter, Remove and Install
– Rockwell (Models F08, F35, F48, F69, F70)
Remove
Control unit – see operation "Control Unit, Remove and
Install (Models F08, F35, F48, F69, F70)". Drive water gutter
– see operation "Crank Drive, Remove and Install (F08, F35,
F48, F69, F70)" or "Electric Drive, Remove and Install (Models F08,
F35, F48, F69, F70)". Pull side guide and rear guide with actuating
cable halfway out of guide rail. Detach bearing of connecting rod
from connecting pin. Detach water gutter guide from connecting rod
of side guide.
Install
|
|
Attach side guide connecting rod bearing to gutter guide
connecting pin. Push side guide and rear guide with actuation cable
into guide rail.
|
|
Adjust
Basic adjustment of both actuation cables – see operation
"Both Actuation Cables, Basic Adjustment (Models F08, F35, F48,
F69, F70)". Adjust drive – see operation "Crank Drive, Adjust
(Models F08, F35, F48, F69, F70)".
Install
Install drive, gutter, actuation unit.
|