Converter and/or Fluid Pump Seal Ring, Replace (AF
13-II/AF 17/AF 20/AF 22)
Remove
Remove transmission – see operations: "Transmission,
Remove and Install (AF 13-II/AF 17)", "Transmission, Remove and
Install (AF 20)" or "Transmission, Remove and Install (AF 22)".
Pull converter from transmission with KM-574 (M8) or KM-899
(M10) (arrows).
Fluid escapes – place pan underneath.
|
|
Remove seal ring from transmission with KM-J-7004 (1) and KM-586
(2).
Install
Drive in new seal ring flush with KM-674 (3).
Insert converter in transmission (with KM-574 or KM-899) –
converter must sit perfectly and engage in guide.
Measure
Measure distance between converter
contact thread and transmission housing contact surface with
calliper gauge (1).
Distance measuring device AF 13-II/AF 17:
|
approx. 12 mm
|
Distance dimensions AF 20/AF 22:
|
approx 13 mm
|
|
|
Install
Install transmission – see operation "Transmission, Remove
and Install (AF 13-II/AF 17)", "Transmission, Remove and Install
(AF 20)" or "Transmission, Remove and Install (AF 22)".
|