C-020 - O2 Sensor Heater Circuit (Bank 1, Sensor 1)

Test

Work Order Description

Nominal Value

T001

Check: Diagnostic Trouble Code stored

  • Read and record diagnostic trouble codes including status

Is the diagnostic trouble code P0135 with status PRESENT stored?

Yes: No:
T002

Check: Interruption of Voltage Supply Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    B166 Sensor - Oxygen, Mixture Control, Heated
  • Remove electrical component from socket:
    K2_X125 Relay - Engine Control Unit
  • Connect fused jumper wire to:
    K2_X125 Relay - Engine Control Unit
    Socket Terminal 87
    &
    Battery voltage
  • Measure voltage between the following terminals:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (wiring harness side) terminal 1
    &
    Ground

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:
T003

Check: Short to Voltage of Ground Circuit

  • Remove fused jumper wire
  • Disconnect wiring harness connector from:
    M3 Motor - Radiator Fan
    and
    A84 Control Unit - Engine
    (Wiring Harness Connector (XC1) )
  • Ignition ON
  • Measure voltage between the following terminals:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

less than 0.3 V

Voltage Measurement Current Value: V
Yes: No:
T004

Check: Component

  • Ignition OFF
  • Measure resistance between the following terminals:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 1
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 2

4 ... 12 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:
T005

Check: Component

  • Measure resistance between the following terminals:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 1
    &
    Ground

greater than 500 kOhm

Resistance Measurement Current Value: kOhm
Yes: No:
T006

Check: Component

  • Ignition OFF
  • Measure resistance between the following terminals:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 1
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 2

greater than 12 Ohm

Resistance Measurement Current Value: Ohm
Yes: No:


Result

Cause Of Fault

E001 Result: Short to Ground/Interruption
  • Short circuit to ground/interruption of circuit between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 49 (XC1)
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (wiring harness side) terminal 2

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E002 Result: Short to Ground
  • Short circuit to ground between:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 1
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 2

or

  • Defective component:
    B166 Sensor - Oxygen, Mixture Control, Heated
E003 Result: Interruption
  • Circuit interruption between:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 1
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 2

or

  • Defective component:
    B166 Sensor - Oxygen, Mixture Control, Heated
E004 Result: Short Circuit in Wiring Harness
  • Short circuit in wiring harness between:
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 1
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (component side) terminal 2

or

  • Defective component:
    B166 Sensor - Oxygen, Mixture Control, Heated
E005 Result: Short to Voltage
  • Short circuit to voltage between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 49 (XC1)
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (wiring harness side) terminal 2
E006 Result: Interruption
  • Circuit interruption between:
    X125 Underhood Electronic Module
    Wiring harness connector (wiring harness side) terminal 29 (XE3)
    &
    B166 Sensor - Oxygen, Mixture Control, Heated
    Wiring harness connector (wiring harness side) terminal 1

or

  • Defective component:
    X125 Underhood Electronic Module

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E007 Result: Defective Component
  • Defective component:
    B166 Sensor - Oxygen, Mixture Control, Heated





C-021 O2 Sensor Heater Circuit (Before Catalyst) > < C-019 Charcoal Canister Purge Valve Circuit