Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage/Ground/Interruption of Voltage Supply
|
- Ignition OFF
- Disconnect wiring harness connector from:
A111 Throttle Valve - Positioner
- Ignition ON
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 3 & Ground
|
4.8 ... 5.2 V
|
|
|
T002
|
Check: Short to Voltage/Interruption of Voltage Supply Circuit
|
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 2 & A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 3
|
4.8 ... 5.2 V
|
|
|
T003
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 5 & Ground
|
less than 0.3 V
|
|
|
T004
|
Check: Component
|
- Diagnostic Tester Data List Parameter
TP Sensor 2 (Throttle Position)
|
less than 0.3 V
|
|
|
T005
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Connect fused jumper wire to:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 3 & A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 5
- Diagnostic Tester Data List Parameter
TP Sensor 2 (Throttle Position)
|
4.8 ... 5.2 V
|
|
|
T006
|
Check: Short to Voltage/Ground/Interruption of Signal Circuit
|
- Remove fused jumper wire
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 6 & Ground
|
less than 0.3 V
|
|
|
T007
|
Check: Component
|
- Diagnostic Tester Data List Parameter
TP Sensor 1 (Throttle Position)
|
less than 0.3 V
|
|
|
T008
|
Check: Short to Ground/Interruption of Signal Circuit
|
- Connect fused jumper wire to:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 3 & A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 6
- Diagnostic Tester Data List Parameter
TP Sensor 1 (Throttle Position)
|
4.8 ... 5.2 V
|
|
|
T009
|
Check: Short to Voltage of Ground Circuit
|
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 2 & Ground
|
less than 0.3 V
|
|
|
T010
|
Check: Short to Voltage of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B69 Air Mass Meter
- Ignition ON
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 2 & Ground
- Disconnect each of the following components/control units consecutively from the wiring harness and repeat the measurement each time:
B39 Sensor - Temperature, Coolant B26 Sensor - Atmospheric Pressure B150 Sensor - Boost Pressure
|
less than 0.3 V
|
|
|
T011
|
Check: Short to Voltage of Ground Circuit
|
- Ignition OFF
- Remove electrical component from socket:
K12_X125 Relay - Radiator Fan
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC7 )
- Ignition ON
- Measure voltage between the following terminals:
A111 Throttle Valve - Positioner Wiring harness connector (wiring harness side) terminal 2 & Ground
|
less than 0.3 V
|
|
|