The following test steps must be performed in the given order. If a fault is found in one test step, the subsequent test steps can be skipped.
Fuses
- Check the following fuses for proper operation:
FE26 Fuse
- If fuse FE26 is defective:
Trouble Codes
- If any of the following trouble codes with status PRESENT are stored, perform the related actions.
- With trouble code P0115 recognised:
- With trouble code P0130, P0134 recognised:
- With trouble code P0136 recognised:
- With trouble code P0443 recognised:
Perform the following troubleshooting:
After successful test/fault repair proceed to the next test step
|
|