vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Throttle Valve Potentiometer (Double Signal), Multec/Trionic (MY 2001,MY 2002 and MY 2003), Simtec (MY 2001 and MY 2002) > < Knock Sensor

Ignition, Primary, Z14XE, Z16XE, Z16YNG

 

Objective:

Analysis of the primary voltage generated in the engine control unit.

Measurement:

Plot of the primary voltage with the engine idling (single display).

Preparation:

Caution - high voltage! Observe safety advice! Engine oil temperature greater than 80°C .

Connections:

INPUT A

COM/TRIGGER

INPUT B

Connect the red measurement lead to terminal A, B, C or D of the ignition coil plug. Connect the black ground lead to ground.

 

 


Procedure Tech 31:

1. Download Reference curve.
2. Start the engine and allow it to idle.

Reference Curve:

Object Number: 2400981  Size: DEFAULT

Procedure Tech 32:

1. Download Setup File.
2. Start engine and allow it to idle.

Setup File:

Reference Curve:

Object Number: 2419073  Size: DEFAULT

Throttle Valve Potentiometer (Double Signal), Multec/Trionic (MY 2001,MY 2002 and MY 2003), Simtec (MY 2001 and MY 2002) > < Knock Sensor