Affected Terminals: -
Possible Trouble Codes: 61, 64
Engine running at idle speed, operating temperature
Vehicle stationary
Press key F 6 in the main menu, select the desired test
using the arrow keys and confirm with YES. Follow the instructions in the
TECH 1 display.
Note:
In this mode, it is possible to vary the maximum amount of
fuel permitted by the control unit in the range from 88 % to 112 % (basic
setting 100 %) using the arrow keys. The limit at which the control unit
starts to regulate the injection quantity can thus be increased or decreased.
This adjustment should be used if the engine does not supply adequate output
or torque or provides excessive output or torque.
|