· With
ignition "ON" the fault is recognized immediately
· Voltage
control relay can be actuated, i. e. trouble codes 62, 63 and 64 not set
· The
voltage level recognized by the control unit at the relevant control unit
output (terminal 45) is 12 V, although the output from the control unit
was set to 0 V (solenoid valve is actuated) (short circuit to battery
voltage)
· Engine
running
· The
fault must be recognized at least 8 times (160 ms).
· If
the fault occurs after the engine is started, the fault is only recognized
after the solenoid valve is actuated
Effects:
· Solenoid
valves (brake band, 1 - 2 / 3 - 4 shifting, 2 -
3 shifting, torque converter clutch) and electrohydraulic pressure
regulator are switched off
· If
the fault is recognized, the following gears can still be shifted manually in
each driving stage (emergency program):
"Driving stage"
(gear) "D"(4), "3"(4), "2"(3), "1"(1)
|