940 L4-2.3L SOHC VIN 88 B230F (1992)
-
Turn off engine.
-
Carry out a leak test with leak detector and note leaks
-
Connect recovery/recycling station for R12
-
Recover R12 from the A/C system. Evacuate A/C system for 10 minutes or until there is a vacuum (about 10 min).
-
Disconnect recovery/recycling station.
-
Repair/replace any leaking components (except for corresponding parts included in the kit).
If the compressor does not start when tested:
-
Check for visible leaks and other visible faults in the system, e.g., loose electrical connections, etc.
-
Connect recovery/recycling station for R12
-
Recover R12 from the A/C system. Evacuate A/C system for 10 minutes or until there is a vacuum (about 10 min).
-
Disconnect recovery/recycling station.
-
Repair/replace any leaking components (except for corresponding parts included in the kit).
Conversion of A/C System
Remove accumulator
Undo:
-
ETF/KRU-valve at bracket. Remove locking clip and valve
-
pipe connectors at the accumulator inlet and outlet.
-
pressure switch connector and remove the pressure switch
-
remove existing 0-rings. Note which size goes where.
-
clamp holding the accumulator.
Lift Out accumulator with clamp.
Cap/plug open pipes to avoid moisture in the system.