CL L4-2156cc 2.2L SOHC F22B1 MFI (1997)
Shift Fork: Testing and Inspection
Shift Fork
NOTE: The synchro sleeve and synchro hub should be replaced as a set.
1. Measure the clearance between each shift fork and its matching synchro sleeve.
-
Standard: 0.35 - 0.65 mm (0.014 - 0.026 inch)
-
Service Limit: 1.00 mm (0.039 inch)
2. If the clearance is more than the service limit, measure the thickness of the shift fork fingers.
-
If the thickness of the shift fork finger is not within the standard, replace the shift fork with a new one.
-
If the thickness of the shift fork finger is within the standard, replace the synchro sleeve with a new one.
3. Measure the clearance between the shift fork and the shift arm.
-
Standard: 0.2 - 0.5 mm (0.008 - 0.020 inch)
-
Service Limit: 0.6 mm (0.024 inch)
4. If the clearance is more than the service limit, measure the width of the shift arm.
-
Standard: 12.9 - 13.0 mm (0.508 - 0.512 inch)
-
If the width of the shift arm is not within the standard, replace the shift arm with a new one.
-
If the width of the shin arm is within the standard, replace the shift fork or shift piece with a new one.