CL TYPE S V6-3.2L SOHC (2001)
25. Check for continuity between PCM connector terminals A14 and B20 or B22.
Is there continuity?
YES - Repair short in the wire between PCM connector terminal A14 and the gauge assembly.
NO - Check for loose terminal fit in PCM connector terminal A14. If necessary, substitute a known good PCM and recheck.