acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Evaporative Check Valve|Testing and Inspection|Page 2395 > < Evaporative Check Valve|Testing and Inspection|Page 2393
Page 2
background image

2. Disconnect the hoses, then remove non-return valve A.

3. Install the parts in the reverse order of removal.

NOTE: Make sure the arrow on the valve points in the correct direction.

Non-Return Valve B Replacement

1. Remove the air cleaner  See: Fuel Delivery and Air Induction/Air Cleaner Housing/Service and Repair.

2. Remove the air bypass outlet pipe  See: Fuel Delivery and Air Induction/Turbocharger/Intercooler/Service and Repair.

3. Disconnect the hoses, then remove non-return valve B.

Evaporative Check Valve|Testing and Inspection|Page 2395 > < Evaporative Check Valve|Testing and Inspection|Page 2393