acura Workshop Repair Guides

Acura (Honda) Workshop Service and Repair Manuals

Troubleshooting - B-CAN System Diagnosis Test Mode 1 and Test Mode 2 (Without the HDS)|Page 3547 > < Troubleshooting - B-CAN System Diagnosis Test Mode 1 and Test Mode 2 (Without the HDS)|Page 3545
Page 1
background image

Information Bus: Component Tests and General Diagnostics
Troubleshooting - B-CAN System Diagnosis Test Mode D

Troubleshooting - B-CAN System Diagnosis Test Mode D

Do this diagnosis if a component that is controlled by the B-CAN system does not run or come on.

NOTE:

-

If the component does not turn off or stop, go to B-CAN System Diagnosis Test Mode C.  See: Troubleshooting - B-CAN System Diagnosis Test
Mode C

-

See the B-CAN system unit input/output index for a list of input and output devices and the control units that monitor the input and controls the
output devices.  See: Description and Operation

-

Always turn the ignition switch within 3 seconds when prompted in the DTC troubleshooting procedures in this section.

1. Check the fuse of the malfunctioning output device.

Is the fuse OK?
YES -  Go to step 2.

 

NO -  Replace the fuse and recheck.

 

2. Check for DTCs by selecting the TEST MODE MENU from the HDS.

Are any DTCs indicated?
YES -  Go to B-CAN System Diagnosis Test Mode A.  See: Troubleshooting - B-CAN System Diagnosis Test Mode A

 

NO -  Go to step 3.

 

3. Turn ON the switch that controls the malfunctioning component.

4. Select DATA LIST from the TEST MODE MENU, and check output signal for the malfunctioning component.

Is there an output signal?
YES -  Go to step 5.

 

NO -  Go to step 9.

 

5. Check the relay and ground, then check for an open or a short in the circuit for the malfunctioning component.

Is the relay and the circuit OK?
YES -  Go to step 6.

 

NO -  Replace the relay or repair the wire circuit.

 

6. Do the function test for the malfunctioning component.

Does the output device pass the function test?
YES -  Go to step 7.

 

NO -  Replace the component.

 

7. With the malfunctioning output device connected, connect a voltmeter between the malfunctioning output device and body ground on the wire that

the control unit uses to control the output device circuit.

8. Select MISC. TEST from the TEST MODE MENU, and do the forced operation test of the malfunctioning component.

Troubleshooting - B-CAN System Diagnosis Test Mode 1 and Test Mode 2 (Without the HDS)|Page 3547 > < Troubleshooting - B-CAN System Diagnosis Test Mode 1 and Test Mode 2 (Without the HDS)|Page 3545