L12 Climate control unit cools too much
The control button operates the passenger compartment air fan normally, but the temperature of the air is not as required.
| Step | Test procedure | Result | Action |
|---|---|---|---|
| 1 | CHECKING AIR TEMPERATURE Check the temperature of the air at the vents (See Test 5040A Data not yet available ) | OK | |
| Ambient temperature at the vents | |||
| Temperature at the vents higher than desired | |||
| 2 | CHECKING SYSTEM PRESSURE Connect the climate control system to the recharging equipment and check the system pressures (See Test 5040B Data not yet available ). | OK | |
| High and low pressure values below correct figures. |
End of diagnosis | ||
| High and low pressure values above correct figures. | |||
| Low pressure value correct, but high pressure value above correct level (rapid compressor cycles as engine rpm rises) | |||
| Low pressure value high and high pressure value below correct levels |
End of diagnosis | ||
| High and low pressure vaules do not alter when the air conditioning is activated. |
End of diagnosis | ||
| 3 | CHECKING CONDENSER FAN Check that the fan cools the condenser correctly. | OK | |
| Electric fan defective |
End of diagnosis | ||
| 4 | CHECKING CIRCUIT CHARGE Check that the system charge is not excessive. | OK | |
| Excessive system charge |
End of diagnosis | ||
| 5 | CHECKING COOLANT CIRCUIT OBSTRUCTIONS Check that the pipes and the filter are not obstructed. | OK | |
| Pipe from compressor to condenser obstructed |
End of diagnosis | ||
| Pipe from condenser to filter obstructed |
End of diagnosis | ||
| Pipe from filter to expansion valve obstructed |
End of diagnosis | ||
| Filter obstructed |
End of diagnosis | ||
| 6 | CONDENSER CHECK Check that the condenser is not blocked. | OK | |
| Condenser blocked |
End of diagnosis | ||
| 7 | EXPANSION VALVE CHECK Check the operation of the expansion valve. | OK | |
| Expansion valve defective |
End of diagnosis | ||
| 8 | CHECKING CORRECT OPERATION Check that the fault is no longer present | OK | Incorrect selection of diagnostic procedure |
| Fault persists | Incorrect selection of diagnostic procedure |