Climate control too cold
- Make
- Alfa Romeo
- Model
- GT Factory Service Manual
- Year
- 2003–2010
- Section
- Climate control › Climate control too cold
CLIMATE CONTROL TOO COLD
The control button operates the passenger compartment air fan normally, but the temperature of the air is not correct.
| Results of the tests | ||||
| 1 | AIR TEMPERATURE CHECK | All OK | Problems met | Operation |
|---|---|---|---|---|
| Check the temperature of the air at the vents | Continue to Step 8 | Ambient temperature at the vents | Continue to Step 2 | |
| Temperature at the vents higher than desired | Continue to Step 3 | |||
| 2 | CHECKING SYSTEM PRESSURE | All OK | Problems met | Operation |
| Connect the climate control system to the recharging equipment and check the system pressures | Continue to Step 8 | High and low pressure values below correct figures | Repressurize the system Op. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE | |
| High and low pressure values above correct figures | Continue to Step 3 | |||
| Low pressure value correct, but high pressure value above correct figure (rapid compressor cycle as engine rpm increases) | Continue to Step 4 | |||
| Low pressure value high and high pressure value below correct figure | Replace the compressor Op. Op. 5040A20 AIR CONDITIONER COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY | |||
| High and low pressure vaules do not alter when the air conditioning is activated. | Replace the compressor Op. Op. 5040A20 AIR CONDITIONER COMPRESSOR - R+R - INCLUDES FLUID LEVEL CHECK AND TOP UP IF NECESSARY | |||
| 3 | CONDENSER FAN CHECK | All OK | Problems met | Operation |
| Check that the fan cools the condenser correctly. | Continue to Step 4 | Electric fan defective | Replace the electric fan Op. | |
| 4 | CIRCUIT LOADING CHECK | All OK | Problems met | Operation |
| Check that the system loading is not excessive. | Continue to Step 5 | System loading excessive. | Restore the correct loading Op. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE | |
| 5 | COOLANT CIRCUIT OBSTRUCTION CHECK | All OK | Problems met | Operation |
1.9 JTD 16V Two-zone climate control system | Check that the pipes and the filter are not obstructed. | Continue to Step 6 | Pipe from condenser to drier filter obstructed | Replace the pipe Op. 5040A52 |
| Filter obstructed | Replace the filter Op. Op. 5040A44 AIR CONDITIONER DEHYDRATING FILTER/ACCUMULATOR - R+R | |||
2.0 JTS 3.2 V6 Two-zone climate control system | Check that the pipes and the filter are not obstructed. | Continue to Step 6 | Pipe from compressor to condenser obstructed | Replace the pipe Op. Op. 5040A50 PIPE FROM COMPRESSOR TO AIR CONDITIONER CONDENSER - R+R |
| Pipe from condenser to filter obstructed | Replace the pipe Op. 5040A52 | |||
| Pipe from filter to evaporator obstructed | Replace the pipe Op. 5040A56 | |||
| Filter obstructed | Replace the filter Op. Op. 5040A44 AIR CONDITIONER DEHYDRATING FILTER/ACCUMULATOR - R+R | |||
| 6 | CONDENSER CHECK | All OK | Problems met | Operation |
| Check that the condenser is not blocked. | Continue to Step 7 | Condenser blocked | Replace the condenser Op. | |
| 7 | EXPANSION VALVE CHECK | All OK | Problems met | Operation |
| Check the operation of the expansion valve. | Continue to Step 8 | Expansion valve defective | Replace the expansion valve Op. | |
| 8 | CHECK ON CORRECT OPERATION | All OK | Problems met | Operation |
| Check that the fault is no longer present | End of diagnosis | |||
Parts & tools for this job For 2003 Alfa Romeo GT
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Alfa Romeo GT 2003 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.