Workshop Manuals Factory service & repair Aston Martin
01 Introduction and safety02 Electrics03 Body and trim04 Air conditioning05 Diagnostic system (PDU)
Aston Martin DB7 Factory Workshop Manual Volume 2: Electrics, Body and Air Conditioning (1994-1998)04 · Air conditioning
04 · Heating & A/C

Ambient Temperature Sensor

Make
Aston Martin
Model
DB7 Factory Workshop Manual Volume 2: Electrics, Body and Air Conditioning
Year
1994–1998
Section
Air conditioning diagnostics › Ambient Temperature Sensor
Air conditioningAmbient Temperature Sensor

The following signals are supported on the Air-Conditioning Control Module. For each signal, The signal name, mnemonic and background information are detailed.

Ambient Temperature Sensor

(AMBTEMP)

A/CCM Pin 34 ref Pin 6

This sensor is located in the right hand blower motor. This signal is used to enable the A/C system to compensate for changes in ambient air temperature. The output to pin 34 is 2.732 volts at 0 degrees Celsius and changes by 0.01 volts for each degree Celsius above or below zero.

Auto-Recirculation Input

(ARECIP)

A/CCM Pin 9 ref Pin 6

This is effectively an On/Off switch for the A/C system and forms part of the fan control switch.

  • Switch Off - Pin 9 should be at ground
  • Switch On - Pin 9 should be at 10+ volts.

When pin 9 is at ground, pin 3 will be at 10+ volts causing the recirculation flaps to open.

Auto-Recirculation Output

(ARECOP)

A/CCM Pin 3 ref Pin 6

This signal will cause the recirculation flaps to close. Operating conditions should be:

  • A/C Off - 10+ volts at pin 3, flaps open.
  • Temp demand minimum - 10+ volts at pin 3, flaps open.
  • Defrost - 0 volts at pin 3, flaps closed.
  • Temp demand max - 0 volts at pin 3, flaps closed.

Auxiliary Battery Positive

(AUX+)

A/CCM Pin 1 ref Vehicle Battery -ve

This signal is the auxiliary supply to the A/CCM. Pin 1 should read battery voltage if the ignition switch is in the auxiliary or ignition on positions. Pin 1 should read 0 volts when the ignition switch is in the Off position or in position III whilst cranking the engine. Loss of this supply will cause total failure of the A/C system.

Clutch Relay Drive Output

(CLUREL)

A/CCM Pin 20 ref Pin 6

This signal responds to the input at pin 5 (evaporator sensor). When pin 5 is between 2.715 and 2.725 volts, pin 20 should read below 1 volt, and the compressor clutch will be switched off. When pin 5 is between 2.735 and 2.745 volts, pin 20 will rise to 10+ volts and the compressor will re-engage.

Centre Vent Solenoid

(CVSOL)

A/CCM Pin 18 ref Pin 6

The centre vent solenoid controls the operation of the centre vent flap. The centre vent will open to increase the cooling capabilities of the vehicle when cooling is selected. In all other conditions, the centre vent will be closed.

  • Solenoid energised: pin 18 should read 10+ volts and the centre vent will be open.
  • Solenoid de-energised; pin 18 should read below 0.5 volts and the centre vent should be closed.

Parts & tools for this job For 1994 Aston Martin DB7

Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.