Compressor Malfunction
- Make
- Aston Martin
- Model
- DB7 Factory Workshop Manual Volume 2: Electrics, Body and Air Conditioning
- Year
- 1994–1998
- Section
- Manifold gauge set › Compressor Malfunction
Air conditioningCompressor Malfunction
Compressor Malfunction
Complaint.
Cooling is not adequate.
Condition
- The low side gauge reading is too high.
- The high gauge reading is too low.
- The sight glass is free of bubbles and the system is fully charged.
- The discharge air from the evaporator is not sufficiently cool.
Diagnosis.
Internal leak in the compressor.
Correction.
- Depressurise the system.
- Renew the compressor and the drier bottle.
- Evacuate the system using a vacuum pump.
- Charge the system with new refrigerant.
- Operate the system and check the performance.
Condenser Malfunction or System Overcharge
Complaint.
Little or no cooling. Overheating of the engine may also be noted.
Condition.
- The low side gauge reading excessively high.
- The high side gauge reading is also excessively high.
- Bubbles may appear occasionally in the sight glass and the liquid line to the evaporator is very hot.
- The discharge air from the evaporator is warm.
Diagnosis.
The condenser not operating correctly through lack of cooling caused by too high a high side pressure. The system may have either a normal or overcharge of refrigerant.
Correction.
- Check the compressor drive belt for correct tension.
- Check the condenser for clogged air passages preventing air flow through the condenser.
- Inspect the condenser mounting for correct radiator clearance.
- Check for correct fan operation.
- Check the coolant pressure cap for correct type and operation.