Air conditioningBlower Motor Test
Blower Motor Test
Face Level: Hot Face Temperature Demand Switch: Minimum
| Differential temp. | 28 | 0 to 200mV |
|---|---|---|
| Temperature demand | 35 | 0 to 200mV |
| Note: Allow the servo motors to come to rest before checking voltage levels. Typical figures are given in brackets. |
| Mode Switch | RH Control | LH Control | RH Feedback | LH Feedback |
|---|---|---|---|---|
| Position | Pin No. 32 | Pin No. 31 | Pin No. 33 | Pin No. 22 |
| Low | 1 - 2V (1.77V) | 1 - 2V (1.77V) | 4 - 6V (5.8V) | 4 - 6V (5.63V) |
| Med | 2 - 3V (2.28V) | 2 - 3V (2.27V) | 3 - 5V (3.7V) | 3 - 5V (3.4V) |
| High | 1 - 2v (1.17V) | 1 - 2V (1.19V) | 1 - 2V (1.22V) | 1 - 2V (1.27V) |
Set Face Differential Pot. to Mid Point
| Mode Switch | RH Control | LH Control | RH Feedback | LH Feedback |
|---|---|---|---|---|
| Position | Pin No. 32 | Pin No. 31 | Pin No. 33 | Pin No. 22 |
| Low | 1 - 2V (1.24V) | 1 - 2V (1.27V) | 6.5 - 9V (8.7V) | 6.5 - 9V (8.7V) |
| Medium | 1 - 2V (1.4V) | 1 - 2V (1.4V) | 6.9 - 9V (7.5V) | 6.5 - 9V (7.5V) |
| High | 2 - 3V (2.2V) | 2 - 3V (2.2V) | 3 - 5V (4.1V) | 3 - 5V (4.0V) |
Set Face Differential Pot. to Cold Face
| Mode Switch | RH Control | LH Control | RH Feedback | LH Feedback |
|---|---|---|---|---|
| Position | Pin No. 32 | Pin No. 31 | Pin No. 33 | Pin No. 22 |
| Low | 1 - 2V (1.67V) | 1 - 2V(1.63V) | 6.5 - 9V(6.25) | 6.5 - 9V(6. IV) |
| Medium | 2 - 3V(2.17) | 2 - 3V(2.1V) | 3 - 5V(4.25V) | 3 - 5V(4.2V) |
| High | 2 - 3V(2.3V) | 2 - 3V(2.2V) | 3 - 5V (3.7V) | 3 - 5V(3.5V) |
Open Water Temperature Switch Needs
Set Temperature Demand Switch to Midpoint Pin No. 35 1.43 -145V
| RH Servo control | Pin 32 | 0 - 0.5V |
|---|---|---|
| LH Servo control | Pin 31 | 0 - 0.5V |
Short Water Temperature Switch Leads
| Mode Switch: Low | ||
|---|---|---|
| Clutch output | Pin 20 | 9.3 - 12.3V |
| RH Servo control | Pin 32 | 1 - 2V |
| LH Servo control | Pin 31 | 1 - 2V |
| Set diff to hot face | Pin 28 | 0 - 200mV |
| Set temp demand to minimum | Pin 35 | 0 - 200mV |
| Recirc. output | Pin 3 | 9.3 - 12.3V |
| High speed relays | Pin 16 | 0 - 200mV |
| Water valve solenoid | Pin 17 | 9.3 - 12.3V |
| Centre vent solenoid | Pin 18 | 9.3 - 12.3V |
| Defrost output | Pin 27 | 0 - 500mV |
| MODE SWITCH: DEFROST | Pin 27 | 150 - 350mV |
| High speed relays | Pin 16 | 9.3-12.3V |
| Lower feedback pot. | Pin 29 | 2.709-3.100V |
| Upper feedback pot. | Pin 30 | 1.714 -2.014V |
| MODE SWITCH: OFF | Pin 44 | 0-IV |
| Recirc. output | Pin 3 | 9.3-12.3V |
‹ Prev Mode Switch: Low or Medium Temperature Demand Switch: Mid-Range - Function Switch: ACNext › Safety Precautions
Parts & tools for this job For 1994 Aston Martin DB7
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Aston Martin DB7 1994 cabin filter
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.