Maintenance
- Make
- Aston Martin
- Model
- V8 Vantage Factory Workshop Manual
- Year
- 2005–2010
- Section
- Heater System › Maintenance
12 Climate controlMaintenance
Maintenance
RHD/LHD Heater Unit (Including ECU)-Renew
| Repair Operation Time (ROT) | |
|---|---|
| Item | Code |
| Heater Unit (Including ECU)-Renew | RHD 12.03.AF |
| Heater Unit (Including ECU)-Renew | LHD 12.03.AD |
To prevent damage to electrical components, always disconnect the vehicle battery when working on the vehicle's electrical system. The earth lead (-ve) must be disconnected first and reconnected last.
- Remove IP unit from vehicle (see Workshop Manual procedure 01.12.AB Facia Assembly LHD Remove for Access and Refit).
- Disconnect multiplugs (x6) from heater unit.
- Remove nuts (x2) and bolt (x1) securing heater unit to IP unit.
- Disconnect tube from 'In car' temperature sensor unit and remove heater unit from IP.
Installation
- Connect tube to 'In car' temperature sensor, install heater unit in position on IP.
- Position heater unit in IP. Install and torque tighten bolt and nuts (x2).
- Connect multiplugs (x6) to heater unit.
- Install IP unit in vehicle (see Workshop Manual procedure 01.12.AB Facia Assembly LHD Remove for Access and Refit).
Always connect the battery earth (-ve) terminal last.
Parts & tools for this job For 2005 Aston Martin V8 Vantage
- PARTOil filterSearch: Aston Martin V8 Vantage 2005 oil filter
- TOOLOil filter wrenchSearch: oil filter wrench
- FLUIDEngine oilSearch: Aston Martin V8 Vantage engine oil
Links open Amazon search results in a new tab. As an Amazon Associate I earn from qualifying purchases.