audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing and installing dust and pollen filter > < Removing and installing centre vent temperature senderG191 - automatically controlled air conditioner
Removing and installing footwell vent temperature senderG192 - automatically controlled air conditioner
Removing and installing footwell vent temperature sender -G192- - automatically controlled air conditioner
  Note
„Read measured values“ in air conditioner „Guided fault-finding“ function → Vehicle diagnostic tester.
   
Removing
–  Remove the dash panel → Rep. gr.70.
–  Remove the central tube → Rep. gr.70.
–  Unplug the connector -2-.
–  Turn the vent temperature sender -3- anti-clockwise and pull it out of the housing.
Installing
Install in reverse order, paying attention to the following:
–  Replace the sealing ring -1- if damaged or defective.
–  Fit the central tube → Rep. gr.70.
Perform the following operations on completion of repair work.
–  Interrogate the event recorder and delete any entries displayed → Vehicle diagnostic tester.
  A87-10880

Removing and installing dust and pollen filter > < Removing and installing centre vent temperature senderG191 - automatically controlled air conditioner