Indicated on the display | Desired function | Fault remedy |
Central flap positioning motor -V70- | t
| The positioning motor for central flap -V70- moves from one limit stop to the other |
| –
| Check that the central flap is moving freely |
|
–
| Open all the dash panel vents |
| –
| The fresh air blower is running |
–
| Air distribution is switched from the footwell to the dash panel vents |
| –
| Using the current flow diagram, check the wiring between positioning motor for central flap -V70- and the operating and display unit for air conditioner/Climatronic -E87- for an open circuit or to see if the wiring has been interchanged |
–
| Check the central flap positioning motor -V70- → Chapter |
–
| Replace the operating and display unit for air conditioner/Climatronic -E87- → Chapter |
|
positioning motor for defrost flap -V107- | t
| The positioning motor for defrost flap -V107- moves from one limit stop to the other |
| –
| Check that the defrost flap is moving freely |
|
–
| Close all the dash panel vents |
| –
| The fresh air blower is running |
–
| Air distribution is switched from the footwell to defrost |
| –
| Using the current flow diagram, check the wiring between positioning motor for defrost flap -V107- and the operating and display unit for air conditioner/Climatronic -E87- for an open circuit or to see if the wiring has been interchanged |
–
| Check the defrost flap positioning motor -V107- → Chapter |
–
| Replace the operating and display unit for air conditioner/Climatronic -E87- → Chapter |
|