Note t
| In the event of there being several simultaneous compressor shut-off criteria (see display zone “1”), the shutoff criteria are either displayed alternately or the display only shows the criterion assigned the highest priority by the operating and display unit for air conditioner/Climatronic -E87-. |
t
| Display zone “1” shows the current compressor shut-off criteria. |
t
| Only compressor shut-off criteria marked with an * are stored in display zones “2”, “3” and “4”. However, they are only stored when they have been active for more than 20 sec. (shut-off criterion “12” is stored after just 12 seconds). |
t
| Display group “015” in display zone “4” shows the sum of the compressor shut-off operations performed since the fault memory was last erased. However, only those cut-off conditions which were not initiated by the operating and display unit for air conditioner/Climatronic -E87- will be saved; they are identified by an *. |
|
|
|