Display zone | Meaning | Explanatory Notes |
1 | Actual feedback value for the potentiometer -G92- (in the temperature flap positioning motor -V68-) | l
| Display value greater than “5” and less than “250” |
l
| Maximum permissible deviation: 3 units from the specified feedback value (only in the range greater than 50 but less than 200) |
|
2 | Target feedback value for the potentiometer -G92- (calculated by the operating and display unit for air conditioner/Climatronic -E87-) | l
| Display range 5 ... 250 |
|
3 | Potentiometer -G92- value ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “heating stop” position (the temperature flap directs the air flow through the heat exchanger) | l
| Display value greater than “5” and less than “50” |
|
4 | Potentiometer -G92- value ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “cooling stop” position (the temperature flap directs the air flow past the heat exchanger) | l
| Display value greater than “200” and less than “250” |
|