audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Display group 005: > < Display group 003:
Display group 004:
Display group 004:
Defrost flap positioning motor -V107-
   
Display zoneMeaningExplanatory Notes
1Actual feedback value for the potentiometer -G135- (in the defrost flap positioning motor -V107-)
l  Display value greater than “5” and less than “250”
l  Maximum permissible deviation: 3 units from the specified feedback value (only in the range greater than 50 but less than 200)
2Target feedback value for the potentiometer in the defrost flap positioning motor -G135- (calculated by the operating and display unit for air conditioner/Climatronic -E87-)
l  Display range 5 ... 250
3Value for the potentiometer in the defrost flap positioning motor -G135- ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “very bottom” position (the defrost flap closed)
l  Display value greater than “5” and less than “50”
4Value for the potentiometer in the defrost flap positioning motor -G135- ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “very top” position (the defrost flap open)
l  Display value greater than “200” and less than “250”

  Note
Note the instructions on display group “003” → Chapter
   

Display group 005: > < Display group 003: