Display zone | Meaning | Explanatory Notes |
1 | Actual feedback value for the potentiometer - central flap positioning motor -G112- (in the central flap positioning motor -V70-) | l
| Display value greater than “5” and less than “250” |
l
| Maximum permissible deviation: 3 units from the specified feedback value (only in the range greater than 50 but less than 200) |
|
2 | Target feedback value for the potentiometer - central flap positioning motor -G112- (calculated by the operating and display unit for air conditioner/Climatronic -E87-) | l
| Display range 5 ... 250 |
|
3 | Value for the potentiometer - central flap positioning motor -G112- ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “very bottom” position (the central flap and the footwell flap are closed, the air flow is directed to the defrost flap) | l
| Display value greater than “5” and less than “50” |
|
4 | Value for the potentiometer - central flap positioning motor -G112- ascertained during “basic setting” and saved in the operating and display unit for air conditioner/Climatronic -E87- with the positioning motor in the “very top” position (the central flap is open, the footwell flap is closed, the air flow is directed to the dash panel vents) | l
| Display value greater than “200” and less than “250” |
|